When a WLAN has to support nomadic devices, a network architect must primarily plan for which component in their design?

A. type of users

B. number of users per location

C. mobility requirements and usage

D. density of users

Browse 60 Q&As
Questions 5

Which two challenges do802.1ig barcode scanners present to a WLAN design? (Select two.)

A. roaming between APs

B. encountering RF interference by devices

C. determining the RF channel bandwidth consumed per Barcode scanner

D. implementing adequate security measures to ensure PCI compliance

E. providing consistent performance on all available channels

Browse 60 Q&As
Questions 6

A network architect is creating a new wireless solution for a customer. Wireless coverage is required throughout all four floors of two buildings on the same campus. Dynamic RF capabilities, including AirMatch, are required. Seamless

roaming is required within and between the two buildings. Each floor will have approximately 20 APs and 6 external APs are required for connectivity between the two buildings.

Given this information, which Aruba solution would be the most cost-effective while still meeting the customer's requirements?

A. An IAP cluster per floor

B. A standalone 7008 controller per floor

C. Two 7205 mobility controllers in a cluster

D. Two 7030 mobility controllers in a cluster

Browse 60 Q&As
Questions 7

A customer has some employees that travel to various locations, where these employees will need Wi-Fi access at these locations. Because many of these locations do not have wireless support, the employees will need to carry an AP

solution with them. Internet connectivity, if it doesn't exist at these locations, will be provided by a national phone company USB wireless card which will be connected to AP. The wireless solution needs minimal bandwidth, but needs to

minimally support 802.1 lac wave 1 devices.

Which Aruba AP wireless solution would meet the needs of these employees most effectively and cost efficiently?

A. 318

B. 303H

C. 365

D. 203R

Browse 60 Q&As
Questions 8

NewStellar has a main corporate campus in a business park with two adjacent buildings. Each building has three floors and each floor is 322 x 175 feet (98 x 53 meters) for 56,350 square feet (5,235 square meters) total. The ceiling for each floor is 12 feet (3.6 meters) high with a dro This floor has a central main corridor with washrooms, stairs, elevators and supply and network cabinets. There are cubicles around the perimeter of the floor. The central part main corridor's dimensions contain 9,350 square feet (870 square meters). Assuming that wireless coverage is not required in the central area, which square footage (square meter) value should a network architect use when determining the number of APs in a capacity design for each floor?

A. 55.750 square feet {5,175 square meters)

B. 56.350 square feet {5,235 square meters)

C. 47.000 square feet {4,365 square meters)

D. 338,100 feet {31,410 square meters)

Browse 60 Q&As
Questions 9

A network architect is redesigning a wireless network. The architect begins by analyzing the number of spatial streams supported by APs of various vendors as well as the wireless devices currently in the network, if the company wants to ensure that new wireless design, including user wireless devices, support Multi-User MIMO (MU-MIMO). Which standard or standards must the wireless products support?

A. Only 802.11ax and 8011.ac

B. Only 802.11ax

C. Only 802.11ax,802.1lac, and 802.l1n

D. Only 802.11ax,802.11ac, 802.11n, and 802.11a

Browse 60 Q&As
Questions 10

Refer to the exhibit.

When planning the use of Cat7 cabling for a SmartRate connection between an ArubaOS AP and an ArubaOS switch, which sections should be considered when calculating distance?

A. A + C

B. A + B

C. A + B + C + D

D. A + B + C

Browse 60 Q&As
Questions 11

A company has two buildings on a campus that are approximately 700 feet (214 meters) apart with a clear line of site. No fiber exists between the buildings; however, there is a need for connecting the networks in the buildings together. The

connection between the two buildings will need to support peak rates over 1 Gbps.

Which solution should the company choose that will meet their requirements as well as being cost- effective?

A. Two outdoor AP 367s

B. Two outdoor AP 387s

C. Two outdoor AP 510s

D. Multi-mode fiber between campus switches

Browse 60 Q&As
Questions 12

A customer is purchasing Aruba 555 APs for a new wireless network. The APs will be pre-staged as campus APs (CAPs) and be managed by a controller solution During the pre-staging process, console access to the APs might be

necessary.

Which console connection cable should the customer purchase for the 555 APs?

A. RJ-45

B. RS-232

C. USB-A

D. Micro-B USB

Browse 60 Q&As
Questions 13

A customer has a need to track traffic patterns and anomalies on a pair of ArubaOS-CX 8400 series switches. Which technology will the customer need to deploy for these switches?

A. Mobility First

B. NetEdit

C. Network Analysis Engine

D. 2 CiearPass

Browse 60 Q&As
Questions 14

A high-end theater venue will be implementing an Aruba wireless solution using ceiling- and wall- mounted APs. The venue wants to ensure the the APs blend into the ceiling and wall environments. What solution should the customer use to ensure that wireless coverage is not hampered?

A. Place the APs above the ceiling and behind the walls

B. Place a strip of tape over the LEDs

C. Order Aruba AP covers for the APs

D. Paint the APs to match the ceilings or walls

Browse 60 Q&As
Questions 15

A network architect plans to use two ArubaOS 5406 switches in a wiring closet configured in a VSF domain The VSF link requires a 40 GDps connection. Which SFP+ transceiver solutions would meet this requirement?

A. QSFP+ LC

B. SFP

C. SmartRate

D. QSFP28

Browse 60 Q&As
Questions 16

A customer is designing a new wired network. The customer requires 50 Gbps uplinks, VSF logical switching, and smart rate port support.

Which of the following switches would meet these requirements?

A. 3810M series

B. 6300 series

C. 5400R series

D. 8300 series

Browse 60 Q&As
Questions 17

A network architect is doing a site survey for a new wireless design One concern the company has with the old wireless network is coverage. In some cases, APs would lose power and some employees in the network would lose wireless connectivity. The new design needs to prevent this issue from occurring. During the site survey, what are best practices to be followed in regards to the dBm signal level and the power of the AP to ensure adequate wireless coverage and minimal overlap of AP signals for the new design?

A. AP power at 75% and a measurement of -90 dBM on the measuring device

B. AP power at 100% and a measurement of -65 dBM on the measuring device

C. AP power at 75% and a measurement of -80 dBM on the measuring device

D. AP power at 50% and a measurement of -65 dBM on the measuring device

Browse 60 Q&As
Questions 18

A company has hired a network architect to replace an existing legacy wireless and wired network The building is one-story and contains four wiring closets Based on the information the network architect gathered from the company, one 48port POE+ switch and three 48-port non-POE+ switches will be placed in each wiring closet. One stacking domain should be created for each wiring closet that supports 40 Gbps uplinks.

Which stacking solution should the architect implement for the floor that meets the requirements and is the most cost-effective'?

A. VSX

B. VSF

C. Backplane stacking

D. Distributed trunking

Browse 60 Q&As
Exam Code: HPE6-A66
Exam Name: Aruba Certified Design Associate Exam
Last Update: Apr 15, 2024
Questions: 60 Q&As

PDF

$45.99

VCE

$49.99

PDF + VCE

$59.99