Certbus > Dell > Dell Certifications > DES-1241 > DES-1241 Online Practice Questions and Answers

DES-1241 Online Practice Questions and Answers

Questions 4

Through which network do external hosts connect to the cluster for data access?

A. Management

B. ICM

C. ICD

D. Storage

Browse 98 Q&As
Questions 5

What is the last step when adding a drive to a Dell EMC PowerStore system?

A. Verify the new drive is seen

B. Add the drive to the pool

C. Backup the keystore

D. Zero the drive

Browse 98 Q&As
Questions 6

Refer to the exhibit.

A Storage Administrator is troubleshooting a Dell EMC PowerStore T hardware issue. They observe that the base enclosure LED circled is blue. What does this indicate?

A. Base enclosure hardware is operating normally

B. Base enclosure has a component hardware fault

C. Cluster has only a single appliance

D. Appliance has a node in service mode

Browse 98 Q&As
Questions 7

How many nodes are in the base enclosure?

A. 2 nodes configured as Active-Standby

B. 1 node with duel connectivity

C. 1 node with high availability enabled

D. 2 nodes configured as Active-Active

Browse 98 Q&As
Questions 8

Which Dell EMC PowerStore network uses an appliance backplane?

A. ICD

B. MPIO

C. Inter-node

D. Inter-cluster management

Browse 98 Q&As
Questions 9

Which formats are available to list alerts?

A. Standard, NVP, CSV and JSON

B. Table, XLS, CSV and JSON

C. Table, NVP, CSV and XLS

D. Table, NVP, CSV and JSON

Browse 98 Q&As
Questions 10

What guidance must to be considered for Service LAN port access of a Dell EMC PowerStore appliance?

A. Always connect multiple appliances to the same hub or switch

B. Never connect multiple appliances to the same hub or switch

C. Never connect the Service laptop directly to the appliance Service LAN port

D. Always removed the management port connections on the appliance

Browse 98 Q&As
Questions 11

While on-site installing a Dell EMC PowerStore T system, the node A embedded module management Ethernet port link LED is off. What does this indicate?

A. Network connection is established

B. No network connection is established

C. Port speed is 1 GB/s

D. Port speed is 10 GB/s

Browse 98 Q&As
Questions 12

What does the command “svc_journalctl -f -g “st_io_monitor”” do?

A. Retrieves log messages from the specified error and watches for re-occurrence

B. Ignores log messages from the specified error and re-occurring errors

C. Rotates the log based on the specified error

D. Deletes all logs before the specified error

Browse 98 Q&As
Questions 13

A Storage Administrator needs to add drives to a base enclosure of a Dell EMC PowerStore 3000X system. The system currently contains 10 750-GB NVMe SCM drives. Which drive configuration maximizes the base enclosure capacity?

A. 11 750-GB NVMe SCM drives in skits 10-20

B. 13 15360-GB NVMe SSD drives in slots 10-22

C. 13 750-GB NVMe SCM drives in slots 10-22

D. 11 15360-GB NVMe SSD drives in slots 10-20

Browse 98 Q&As
Questions 14

Which experienced administrator role needs to address a warning about configuring VLTi?

A. Storage

B. VMware distributed switch

C. Network

D. NAS

Browse 98 Q&As
Questions 15

Which account credentials are needed to run diagnostic commands?

A. root

B. service

C. console

D. admin

Browse 98 Q&As
Questions 16

How is a service laptop IP configured to connect to the Service LAN port of a Dell EMC PowerStore node?

A. Static IP: 128.221.1.249 and netmask: 255.255.255.0

B. Obtain IP address from DHCP on PowerStore

C. Static IP: 169.254.1.249 and netmask: 255.0.0.0

D. Leave IP address and netmask unconfigured

Browse 98 Q&As
Questions 17

A Storage Administrator notices a Critical alert present in Dell EMC PowerStore Manager relating to data integrity. What action within the alert details slide-out panel is helpful in troubleshooting the problem?

A. Select the Gather Support Materials from Service and Support

B. Access the Repair Flow link to schedule a support engagement

C. Examine Notifications to obtain a list of corrective actions

D. Re-engage support through previous listed Related Events

Browse 98 Q&As
Questions 18

What is an alternative way to collect logs instead of using the Dell EMC PowerStore manager GUI?

A. Data Collect using Service Container

B. USB stick inserted into the system

C. Data Collect using vCenter

D. Discovery Utility

Browse 98 Q&As
Exam Code: DES-1241
Exam Name: Specialist - Platform Engineer, PowerStore
Last Update: Apr 28, 2024
Questions: 98 Q&As

PDF

$45.99

VCE

$49.99

PDF + VCE

$59.99